( Manufacturer Part Number: 7100138823 ), ( Type: Unapproved, Building Materials, Fire Protection ), ( Item Height: 0.226 Mm ), ( Item Width: 0.34 M0.34 ), ( Item Length: 0.582 M0.582 ), ( Fire Rating: 3 Hr ), ( Overall Diameter: 4 In, 102 Mm ), ( Product Color: Red ), ( Product Type: Cast-in Device ), ( Water-tight: No ), ( Eclass 14 Classification Group: 15310200 ), ( Width: 0.37 Yd, 0.34 M ), ( Height: 0.25 Yd, 0.23 M ), ( Length: 0.64 Yd, 0.58 M ), ( Volume: 44.72 Dm3 ), ( Weight: 167.2 Oz, 4740 G ), ( Country Of Origin: United States ), ( Sold As: Case ), ( Lead Time: 2 Days )
The 3M Scott Fire-Dex 7100138823 Fire Barrier Cast-in Device, also known as a 4MCID, is a critical component in the fire protection system for pipes and cable trays. This device is specifically designed to prevent the spread of fire and hot gases through penetrations in fire-rated walls and floors.
The 3M Fire Barrier Cast-in Device is a factory-prepared, intumescent material that expands spherically when exposed to fire conditions. Its advanced design ensures complete seal integrity, even under high pressure differentials, providing an effective fire stop solution for pipes and cable trays up to 12 inches in diameter.
The device's intumescent material is made of a high-density, closed-cell, low-smoke, and low-toxicity foam. It is puncture-resistant and able to withstand significant compressive loads, guaranteeing reliable performance in the event of a fire. Additionally, the material is non-combustible and does not support combustion, further contributing to its fire-stopping capabilities.
The device is designed for easy and precise installation using a specially engineered casting tool. Its one-piece, isostatic molding enhances the uniformity of the expanded foam, ensuring a consistent firestop across the entire penetration. The device also comes with an optional Class 'A' fire-rated, reinforced rod, which further enhances its mechanical load-bearing capacity.
In summary, the 3M Fire Barrier Cast-in Device 7100138823 is an effective and reliable solution for preventing the spread of fire and hot gases through penetrations in fire-rated walls and floors. Its advanced design offers the benefits of uniform expansion, ease of installation, and high load-bearing capacity, making it an essential component in the fire protection systems for buildings and critical infrastructure applications.
The 3M 7100138823 Fire Barrier Cast-in Device is a product designed to provide additional fire protection to piping systems. This device can help prevent the spread of fire and reduce the risk of damage to property and potential safety hazards. Here are the pros and cons of investing in this fire barrier cast-in device.
Pros:1. Improved Fire Safety: The primary advantage of using a fire barriercast-in device is the enhanced fire safety it provides. The device creates a physical barrier between the fire and the piping system, preventing the spread of fire and potentially containing fires within their point of origin.
2. Compliance with Regulations: In many industries and applications, fire safety regulations require the use of specific fire barriers or fire-resistant materials. By installing fire barrier cast-in devices, you can ensure compliance with these regulations and potentially avoid penalties or fines.
3. Reduced Risk of Damage: Fire can cause extensive damage to piping systems, leading to costly repairs and potentially dangerous leakages. Fire barrier cast-in devices can help minimize this risk by protecting the pipes from fire damage.
4. Easy Installation: The 3M 7100138823 Fire Barrier Cast-in Device is designed for easy installation during the piping process. This can save time and labor costs compared to other fire protection systems.
Cons:1. Additional Cost: The use of fire barrier cast-in devices adds an additional cost to the overall piping project. While the long-term benefits can justify the investment, it is important to consider the upfront cost.
2. Limited Application: The 3M 7100138823 Fire Barrier Cast-in Device is designed for specific types of pipes and materials. It may not be applicable to all piping systems, limiting its overall utility.
3. Maintenance Requirements: While the device requires minimal maintenance, it is essential to ensure that it remains in good working condition. Regular inspections and checks are necessary to maintain the effectiveness of the fire barrier.
Conclusion:The 3M 7100138823 Fire Barrier Cast-in Device offers significant benefits in terms of enhanced fire safety, compliance with regulations, reduced risk of damage, and ease of installation. However, the added cost and limited application may be a consideration. Ultimately, the decision to invest in this device should be based on your specific piping requirements, potential fire risk, and budget.
Recommendation:For industries and applications where fire safety is critical and piping systems are potentially susceptible to fire damage, the 3M 7100138823 Fire Barrier Cast-in Device is a worthwhile investment. Conversely, for lower-risk applications or those with minimal budget constraints, this device may not be the most cost-effective solution. It is essential to weigh the benefits and costs carefully and consult with a piping expert or industry professional to determine the best solution for your specific application.
3M Fire Barrier Cast-in Device 4MCID, for Metal Pipes, 4 Inch Manufacturer: Part Number. Color and Appearance Product Colored. Other Details Water-tightwad Tighten. Its black cap, easily visible after pouring, signifies it as a pass-through device for metallic penetrates.
3M Fire Barrier Cast-In Devices for Metal Pipes provide one-step fire stopping penetrations through fire-rated concrete floor assemblies. Instead of drilling holes, installers simply attach the devices directly to floor decking, pour slabs around them and route penetrates after curing. Scientists, researchers and marketers work across countries subjects to solve challenges big small. The device secures easily to floor decking, and its one-piece design withstands the everyday impact wear of construction site even at level.
height are easily adjustable, and these in tumescent devices rated for up to 3-hour fire protection.Simply a Better Way Fire stop, Fire stopping through concrete used mean three things: pouring the concrete, drilling core holes, fire stopping later. Our 3M Fire Barrier Cast-In Devices for Metal Pipes eliminate the time and expense of fire stopping metallic penetrates using extra materials such as pipe devices, strips caulk, allowing secure, permanent fire stop installation before slabs are poured.